GOODMAN GPC 14 SEER R-410A TECHNICAL MANUAL Pdf Download (2024)

GOODMAN GPC 14 SEER R-410A TECHNICAL MANUAL Pdf Download (1)
  1. Manuals
  2. Brands
  3. Goodman Manuals
  4. Air Conditioner
  5. GPC 14 SEER R-410A
  6. Technical manual

Gpc 14 seer r-410a package air conditioners with r-410a

Hide thumbs

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Table Of Contents 27

Advertisem*nt

Table of Contents

  • 1 Product Identification
  • 2 Product Design
  • 3 Outside Slab Installation - Horizontal (H)
  • 4 Rooftop Installation - Horizontal (H)
  • 5 Electrical Data
  • 6 Product Dimensions
  • 7 Package Cooling Specifications
  • 8 Accessories
  • 9 Blower Performance Data
  • 10 BTU Output Vs Temperature Rise Chart
  • 11 Cooling Performance Data
  • 12 Performance Test
  • 13 Cooling Performance Data
  • 14 Wiring Diagrams
  • Download this manual

GPC 14 SEER R-410A

Package Air Conditioners

Refer to Service Manual RS6300011 (Horizontal)

for installation, operation, and troubleshooting information.

All safety information must be followed as provided in the Service Manual.

Refer to the appropriate Parts Catalog for part number information.

Models listed on page 3.

Models qualify for the 2009 and 2010 Federal Tax Credits for Energy Efficiency**

**Note that these tax credits are subject to specific requirements set forth in the American Recovery and

Reinvestment Act of 2009 and in the Internal Revenue Code. Goodman recommends that consumers consult

a tax professional if they have questions about the applicability of these credits.

This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not

assume any responsibility for property damage or personal injury due to improper service procedures or

services performed by an unqualified person.

TECHNICAL MANU

TECHNICAL MANU AL

TECHNICAL MANU

TECHNICAL MANU

TECHNICAL MANU

with R-410A

Copyright © 2009 Goodman Manufacturing Company, L.P.

AL

AL

AL

AL

RT6322007r2

August 2009

Table ofContents

NextPage
  • 1
  • 2
  • 3
  • 4
  • 5

Advertisem*nt

Table of Contents

GOODMAN GPC 14 SEER R-410A TECHNICAL MANUAL Pdf Download (2)

Related Manuals for Goodman GPC 14 SEER R-410A

  • Air Conditioner Goodman GPC14H Specifications

    2- to 5-ton packaged air conditioner up to 14 seer cooling capacity: 24,000 - 57,500 btu/h (20 pages)

  • Air Conditioner Goodman GPC1424H41AB Repair Parts

    Gpc14 h-series r410-a package coolers (14 pages)

  • Air Conditioner Goodman 13 SEER GPC13H Specifications

    Aire acondicionado embalado (20 pages)

  • Air Conditioner Goodman GPC13H Specifications

    2- to 5-ton packaged air conditioner 13 seer / r-410a (36 pages)

  • Air Conditioner Goodman 13 SEER GPC13M Product Specifications

    Aire acondicionado tipo paquete (12 pages)

  • Air Conditioner Goodman GPC15 SEER Technical Manual

    Multi-position package air conditioners with r-410a (25 pages)

  • Air Conditioner Goodman GPH16 Installation Instructions Manual

    15/16 seer “h” series self-contained package air conditioners and heat pump units with r-410a (20 pages)

  • Air Conditioner Goodman GPC13 M Series Technical Manual

    Gpc13 m series multi-position single phase package air conditioners with r-410a (24 pages)

  • Air Conditioner Goodman GPC13 H-Series Repair Parts

    Package coolers (14 pages)

  • Self contained package air conditioners and heat pumps (12 pages)

  • Air Conditioner Goodman GPC1336M41 Installation Instructions Manual

    Air conditioners and heat pump unitsgpc/gph 13 seer m serieswith r-410a (16 pages)

  • Air Conditioner Goodman GPC "M" Series Installation Instructions Manual

    Self-contained package air conditioners and heat pump units (24 pages)

  • Air Conditioner Goodman GPC 13 SEER H Series Installation Instructions Manual

    Air conditioners and heat pump units (20 pages)

  • Air Conditioner Goodman H Series Installation Instructions Manual

    Self-contained package air conditioners and heat pump units with r-410a (20 pages)

  • Air Conditioner Goodman PC 13 SEER R-410A Technical Manual

    Package air conditioners with r-410a (48 pages)

  • A/gpg13 m series w/r410a single package gas-electric heating & cooling unit (40 pages)

Summary of Contents for Goodman GPC 14 SEER R-410A

  • Page 1 RT6322007r2 August 2009 This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person.
  • Page 2: Product Identification

    Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Goodman will not be responsible Installation and repair of this unit WARNING WARNING...
  • Page 3 **Note that these tax credits are subject to specific requirements set forth in the American Recovery and Reinvestment Act of 2009 and in the Internal Revenue Code. Goodman recommends that consumers consult a tax professional if they have questions about the applicability of these credits.
  • Page 4: Product Design

    PRODUCT DESIGN GPC Package Cooling Units are designed for outdoor instal- Due to their design Scroll Compressors are inherently lations only in either residential or light commercial applica- more tolerant of liquid refrigerant. NOTE: Even though the tions. compressor section of a Scroll compressor is more toler- ant of liquid refrigerant, continued floodback or flooded The connecting ductwork (Supply and Return) can be con- start conditions may wash oil from the bearing surfaces...
  • Page 5 PRODUCT DESIGN In installations where the unit is installed above ground level and not serviceable from the ground (Example: Roof Top in- stallations), the installer must provide service platform for ser- 36" vice person with rails or guards in accordance with local codes or ordinances or in their absence with the latest edition of the Uniform Mechanical Code Section 305.
  • Page 6 PRODUCT DESIGN GPC14[24-60]H41A* HKR ELECTRICAL DATA Circuit #1 Circuit #2 Maximum Maximum Actual Minimum Circuit Minimum Circuit Model and Heat Kit Usage kW & BTU Overcurrent Overcurrent Ampacity Ampacity at 240V Protection (amps) Protection (amps) at 208 / 240V at 208 / 240V at 208 / 240V at 208 / 240V GPH1424H41A*...
  • Page 7: Product Dimensions

    PRODUCT DIMENSIONS GPC14[24-60]H41A* 14.000 4.512 4.500 14.000 6.500 14.000 SUPPLY RETURN BACK VI EW (DUCT OPENINGS) 66.542 34.075 Chassis Model GPC1424 30½ Small GPC1430 30½ GPC1436 35½ Medium GPC1442 35½ GPC1448 38½ Large GPC1460 38½ Dimensions in inches...
  • Page 8 PACKAGE COOLING SPECIFICATIONS GPC14[24-36]H41A* GPC1424H41* GPC1430H41* GPC1436H41* COOLING CAPACITY, BTUH 24,600 28,400 35,600 COOLING CAPACITY SEER / EER 14.5 / 12.1 14.0 / 12.0 14.0 / 12.0 UNIT VOLTAGE (NAMEPLATE) 208-230/1/60 208-230/1/60 208-230/1/60 AMPS (TOTAL) 10.5 13.16 20.06 ELECTRICAL SPECIFICATION MINIMUM CIRCUIT AMPACITY 12.5 15.6...
  • Page 9 PACKAGE COOLING SPECIFICATIONS GPC14[42-60]H41* GPC1442H41* GPC1448H41* GPC1460H41* COOLING CAPACITY, BTUH 40,500 46,500 57,500 COOLING CAPACITY SEER / EER 14.5 / 12.0 14.5 / 12.1 14.2 / 12.0 VOLTAGE (NAMEPLATE) 208-230/1/60 208-230/1/60 208-230/1/60 UNIT ELECTRICAL AMPS (TOTAL) 22.2 24.2 30.7 SPECIFICATION MINIMUM CIRCUIT AMPACITY 26.6 29.1...
  • Page 10 GPC14[24-60]H41A* ACCESSORIES ACCESSORIES - GPC/GPH****H UNITS Part Number Description OT18-60A Outdoor Thermostat Kit w/Lockout Stat OT/EHR18-60 Emergency Heat Relay Kit Electric Heat Kit PCCP101-103 Roof Curb PCP101-103 Downflow Plenum Kit PCP101-103R8 Downflow Plenum Kit w/ R-8 Insulation PCEC101-103 Downflow Economizer for GPC-(H) A/C - To Be Used With PCP101-103 PCEH101-103 Downflow Economizer for GPH-(H) Heat Pump - To Be Used With PCP101-103 PCMD101-103...
  • Page 11: Blower Performance Data

    GPC14[24-60]H41A* BLOWER PERFORMANCE DATA Dry Coil Data E.S.P (In. of H Model Speed Volts WATTS T2,T3 WATTS 1061 T4, T5 WATTS 1022 WATTS 1103 1063 1012 T2,T3 WATTS 1285 1240 1202 1163 1124 1076 1046 1003 T4, T5 WATTS 1234 1111 1071 1024...
  • Page 12 BLOWER PERFORMANCE DATA RISE TEMPERATURE...
  • Page 13 COOLING PERFORMANCE DATA GPC1424H41A*...
  • Page 14 COOLING PERFORMANCE DATA GPC1424H41A*...
  • Page 15 COOLING PERFORMANCE DATA GPC1430H41A*...
  • Page 16 COOLING PERFORMANCE DATA GPC1430H41A*...
  • Page 17 COOLING PERFORMANCE DATA GPC1436H41A*...
  • Page 18 COOLING PERFORMANCE DATA GPC1436H41A*...
  • Page 19 COOLING PERFORMANCE DATA GPC1442H41A*...
  • Page 20 COOLING PERFORMANCE DATA GPC1442H41A*...
  • Page 21 COOLING PERFORMANCE DATA GPC1448H41A*...
  • Page 22 COOLING PERFORMANCE DATA GPC1448H41A*...
  • Page 23 COOLING PERFORMANCE DATA GPC1460H41A*...
  • Page 24 COOLING PERFORMANCE DATA GPC1460H41A*...
  • Page 25: Cooling Performance Data

    COOLING PERFORMANCE DATA PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1.
  • Page 26: Wiring Diagrams

    WIRING DIAGRAMS GPC14[24-60]H41A* NOTE #3 SEE NOTE 5 LVJB RCCF (IF USED) SEE NOTE 4 CONTROL C L G N 1 2 3 COMP SEE NOTE 2 COMPONENT LEGEND FACTORY WIRING SUPPLY VOLTAGE LINE VOLTAGE CONTACTOR 208-240/1/60 LOW VOLTAGE CONDENSER MOTOR OPTINAL HIGH COMP COMPRESSOR...

This manual is also suitable for:

Gpc1424h41aGpc1430h41aGpc1436h41aGpc1442h41aGpc1448h41aGpc1460h41a

GOODMAN GPC 14 SEER R-410A TECHNICAL MANUAL Pdf Download (2024)

FAQs

How to manually reset a Goodman AC unit? ›

To reset the air conditioner, once you have located the reset button, look for the circuit breaker in the electrical power service panel, corresponding to your Goodman air conditioner system. On searching the reset button, hold it down for about 20 seconds and release. If the AC does not restart, then repeat the step.

How to decode Goodman model numbers? ›

Goodman serial numbers are 10 digit numerical where the month and year are encoded in the first 4 digits. The year is the first 2 and the month the second 2. For example 1404123456 is manufactured is April 2014. Modern Rheem systems use two styles of date encoded in the serial number.

What kind of freon does a Goodman air conditioner hold? ›

Goodman became the world's first company to succeed in applying R-32 to air conditioners by leveraging its expertise as the only manufacturer that develops and manufactures both air conditioners and refrigerants. Currently, R-410A is the refrigerant most commonly used in developed countries.

What is the life span of a Goodman AC? ›

How long will a Goodman AC last? Goodman air conditioners have an average lifespan of 10 to 15 years. However, appropriate usage and ongoing maintenance can further extend the life of your Goodman HVAC system.

What is dirty sock syndrome Goodman? ›

What is dirty sock syndrome? An unpleasant odor (i.e. wet, dirty sock smell) that comes from micro-organisms growing on the cooling coil surface, in the crevices of the tubes and fin stock of the indoor coil and in the drain pan.

How to tell how many tons a Goodman AC unit is? ›

LOOK AT THE MODEL NUMBER OF THE UNIT ,IN THE MODEL NUMBER THERE WILL BE A NUMBER THAT WILL BE ONE OF THE FOLLOWING,12,18,24,30,36,42,48,54,60 THESE NUMBERS REPRESENT FROM A 1 TON TO A 5 TON SYSTEM. 12 1 TON ,18 TON AND A HALF,24 TWO TONS ,30 TWO AND A HALF TONS,36 THREE TON,42 THREE AND A HALF TON.

Can you tell SEER rating by model number? ›

Most new air conditioners contain a yellow sticker labeled “Energy Guide” where you can find the SEER rating. You can also find it near the top of the air conditioner's manufacturer label by the model and serial number.

How do you read Goodman SEER rating? ›

How To Find The SEER Rating. Head over to your cooling system and look for a yellow and black “energyguide” sticker, which can usually be located on the side of the condenser. If this sticker is still in tact, it will tell you the Seasonal Energy Efficiency Ratio in large numbers.

Will R-410A be phased out? ›

Due to the environmental impact of R-410A, the Environmental Protection Agency (EPA) has announced that it will be phased out and replaced by more eco-friendly alternatives. In this article, we will provide a comprehensive guide to the R-410A refrigerant phase out and what it means for homeowners.

What Freon will replace 410A? ›

What are my options for replacing R-410A? Because there are no retrofits for R410A, a replacement is needed. The replacements for R-410A are the two A2Ls, Forane® R-32 and R-454B. Forane® R-32 can be used in new equipment designed specifically for mildly flammable refrigerants as a replacement for R-410A equipment.

What is the new refrigerant in 2025? ›

What refrigerant will replace R-410A in 2025? Lennox has chosen to replace R-410A, with our 2025 Compliant Refrigerant, R-454B.

Is Goodman a reliable air conditioner? ›

Goodman HVAC systems aren't the most technologically advanced or the most energy efficient, but they are some of the most reliable. They're also relatively affordable given their quality, which is backed by a 10-year limited parts warranty and either a two- or 10-year unit replacement warranty.

What is the most common problem in AC unit? ›

Drainage Problems

One of the most common air conditioner problems is drainage. If your AC unit leaks, there is an issue with its draining system. The condensate for home AC units should go outside through a pipe, not onto your walls or floors. The common diagnosis is a clogged condensation drain.

Why is my Goodman AC unit not blowing cold air? ›

Condenser Coils are Dirty

If the coils are significantly dirty, the air conditioner will not be able to maintain the proper temperature, and the compressor will run continuously in an attempt to cool the room. Check the condenser coils to determine if they are dirty. If the condenser coils are dirty, clean them.

Is Goodman or Carrier better? ›

Based on our comparison between these two brands' levels of reliability and associated costs/warranties, we recommend going with Carrier if you're looking for high quality and dependability without breaking your budget; alternatively, if you're looking for great value within a slightly lower price point with good ...

Top Articles
Latest Posts
Article information

Author: Carlyn Walter

Last Updated:

Views: 5974

Rating: 5 / 5 (70 voted)

Reviews: 93% of readers found this page helpful

Author information

Name: Carlyn Walter

Birthday: 1996-01-03

Address: Suite 452 40815 Denyse Extensions, Sengermouth, OR 42374

Phone: +8501809515404

Job: Manufacturing Technician

Hobby: Table tennis, Archery, Vacation, Metal detecting, Yo-yoing, Crocheting, Creative writing

Introduction: My name is Carlyn Walter, I am a lively, glamorous, healthy, clean, powerful, calm, combative person who loves writing and wants to share my knowledge and understanding with you.